Our Paint & Powder Coating Division offers a full service from supply
of a simple spraybooth to a Fully Automated Paint Line

Introduction
These booths are designed to remove fumes from industrial environments such as paint spray shops, ensuring healthy and suitable working conditions and compliance with inspectorate requirements. Special paper filters are used to which any sticky particles adhere, allowing a large volume of fume laden air to be extracted from the area.

 

Applications
Manual paint spraying
Automatic paint spraying
Polishing/Finishing
Adhesive spraying
Fume extraction
Air replacement

Photo Gallery Just click on the picture to expand

 

top or bottom outlet

Features
Simple, economical maintenance.
Replacement of disposable filters takes only a few minutes.
Complies with all current recommendations and requirements.
All modular construction - any size or shape in 1 metre wide increments is possible.
Prompt delivery.
Belt driven fans with external motors - flameproof or totally enclosed.
Supplied complete with non-flameproof D.O.L starter(s).
Full carton of highly efficient paper filters included as standard.
Delivered in easy to assemble kit form made of all galvanised steel sections.
Full assembly and installation service available.
All RDM Dryfilter Spraybooths are offered with a comprehensive 12 month warranty as well as the option for a service contract which offers priority Service and technical support.

conveyorised type

STANDARD SPECIFICATIONS
Construction: RDM only use first quality 18 SWG galvanised steel to form a modular bolted panelwork system, 16 SWG, or higher are used in support panels. All panels have a 40mm/15mm double folded return edges for stiffness. All bolts are bright zinc plated. Standard panel sizes from 500mm x 500mm to 1000mm x 2000mm in increments of 500mm. All panels have identical hole centres for maximum interchangeability. Control Gear: One direct-on-line no volt release type push button starter, with thermal overload housed in an IP55 enclosure is supplied for each motor.

complete sprayroom

Extraction Filters: Either, 'Andrea' paper corrugated filters, usually two tiers, each tier is 900mm high and the full width of the booth. The filter is retained in sturdy galvanised steel frames offering simple filter replacement. Or, fibre glass 'soil and strip' filters, similar dimensions to the andrea type, with modified steel frames which include a course steel mesh with hooks onto which the filters can be placed.

expansion chamber type

Fans: All fans are of the belt driven axial flow type with polypropylene or nylon aerofoil section impellors. All bearings are sealed and the belt tunnel is sealed from the airstream. External motors sit on large adjustable plates. Most fan cases have integral access doors. A welded mesh finger guard protects the fan inlet and is retained by the fan fixing bolts.

waterwash booth

Extraction Rates: Typically these are designed to provide a minimum average face velocity of 150 feet per minute and better than 3500 cubic feet per minute per linear metre of booth.

Motors: 3 phase - 415 volts - 50 Hz as standard, squirrel cage type. Available to IP54, IP55, or fully flameproof layouts.

Please click on the table to see more technical information

Lighting: (When supplied) Special 18 SWG panels for roof, or sides with a strengthening frame spot welded into place carry a rough cast wired glass insert. Glass is either retained by a rubber seal, or sits on a ribbonseal strip. Illumination is provided by standard twin fluorescent lights usually 5ft long, complete with a wide angle reflector. Side lights are mounted on heavy duty steel hinges.

Dimensions

To enlarge these diagrams click on the pictures

 

Filter

 

Construction

BACK TO TOP


Introduction
These booths are designed to remove high levels of toxic fumes from spray shops and other industrial environments, ensuring healthy and suitable working conditions, and compliance with inspectorate requirements.

complete sprayrooms

Applications
Large volume paint spraying
Polishing/Finishing
Two pack/isocyanate spraying
Fume extraction

conveyorised type

Features
No replaceable filters
Complies with all current recommendations and requirements.
All modular construction - any size or shape in 1 metre wide increments is possible.
Prompt delivery.
Stainless steel water curtains.
Heavy duty pump set.
Belt driven fans with external motors - flameproof or totally enclosed.
Supplied complete with non-flameproof starter(s), pack of chemicals, sealants and fixings.
Full assembly and installation service available.

wash tower ONLY

STANDARD SPECIFICATIONS
Construction: RDM only use first quality 18 SWG galvanised steel to form a modular bolted panelwork system, 16 SWG, or higher are used in support panels. All panels have a 40mm/15mm double folded return edges for stiffness. All bolts are bright zinc plated. Standard panel sizes from 500mm x 500mm to 1000mm x 2000mm in increments of 500mm. All panels have identical hole centres for maximum interchangeability.

Down Draught Type

Control Gear: One direct-on-line no volt release type push button starter, with thermal overload housed in an IP55 enclosure is supplied for each motor.

 

Dryfilter Booth

Pump Set: A heavy duty self priming centrifugal pump is mounted on a stand alongside the water tank with 2½" nominal bore steel delivery pipes complete with a flexible inlet connection, giving a typical circulation rate of 850 litres per minute.

Water Scrubb System: A 2½" nominal bore steel manifold pipe runs across the full length of the wash tower. Three brass spray nozzles per metre length feed from the pipe. Each nozzle is 12.7mm diameter, hollow cone type. Nominal spray pressure of 20PSI. One ¾" nominal bore riser pipe per metre section with a brass gate valve spplies water to troughs at the top of the water curtain.

Water Recovery: The extracted water laden air strikes a minimum of six angled, oversized baffle plates which trap any airborne water particles. The air is then caused to turn sharply into the plenum chamber to centrifugally remove any remaining moisture.

Chemicals: Booths supplied as standard with a pack of spraybooth addative. Liquid or powder chemicals are available to suit specific applications.

Fans: All fans are of the belt driven axial flow type with polypropylene or nylon aerofoil section impellors. All bearings are sealed and the belt tunnel is sealed from the airstream. External motors sit on large adjustable plates. Most fan cases have integral access doors.

Extraction Rates: Typically these are designed to provide a minimum average face velocity of 150 feet per minute and better than 3500 cubic feet per minute per linear metre of booth.

Motors: 3 phase - 415 volts - 50 Hz as standard, squirrel cage type. Available to IP54, IP55, or fully flameproof layouts.

Lighting: (When supplied) Special 18 SWG panels for roof, or sides with a strengthening frame spot welded into place carry a rough cast wired glass insert. Glass is either retained by a rubber seal, or sits on a ribbonseal strip. Illumination is provided by standard twin fluorescent lights usually 5ft long, complete with a wide angle reflector. Side lights are mounted on heavy duty steel hinges.

Water Curtain: In one metre sections across full length of wash tower. Each section has a galvanised steel trough at the top with brass levelling screws, a rolled galvanised steel scroll with angle and reach adjustment and a bright, 18 SWG stainless steel front curtain one metre high clipped into place for easy maintenance removal.

Water Tank: Of first quality 16 SWG galvanised steel sheets folded into one metre wide modular sections with returned edge flanges which bolt together and sealed using 'Ribbonseal' waterproof sealant. The assembled tank incorporates a seperate small weir tank housing a ball-cock filler as well as a removable perforated steel water filter for the pump inlet. Tank capacity 350 litres per metre length.

To enlarge the images just clcik on them.

 

BACK TO TOP
 


RDM Industrial Services Limited
Tel: +44 161 643 9333
Fax: +44 161 655 3467
Email sales@rdmengineering.co.uk