External
view of an RDM Sprayroom
Standard
Options
Choice of Dryfilter or Waterwash extraction systems.
Side wall extraction or downdraught air flow system
with
gridded floor.
Single skinned or double skinned insulated steel manufacture.
Galvanised, Stainless Steel or Painted surface finishes.
Filtered 'shop air' inlet system or pressurised air
replenishment or fully integrated heated air replacement
system with controls.
Gas, electric, oil or steam heating mediums, direct
or indirect.
Air conditioning system with cooling and humidity controls.
Roller or Sliding shutter door or swing doors.
Various light fittings and window systems

Internall
view of an RDM Sprayroom
Standard
Features
Full 12 months warranty
Substantial 18swg/16swg steel construction with sectional
support steelwork suitably stiffened to allow maintenance
operatives to stand on top.
Twin Fluorescent light fittings mounted behind glass
insert panels located on a sealant bead. Air input filters
sit in hinged steel mesh retaining frames and are of
the roll type to reduce replacement costs. Air input
systems are lined with sound deadening materials. All
fuel heated plants conform to British Standards.
Heated plants are complete with full control panel system.
C.E. Approved
Photo
Gallery
Click
on the pictures to enlarge
  
Control
System
Digital
programmable temperature controller.
Electronic overtemperature device.
All gas controls to safety standards.
Pre-start purge and cool timers.
Motor controls and interlocks.
Air flow proving switch(es).
Isolator and line fuses.
Status indicator lamps.
Chart recorder (optional).
Process timer with alarm (optional).
|